Hi Team, I am currently playing with signoz dashboards on a self hosted env(version 0.46.0), First of all very good tool so far, a lot of effort has gone into the tool as seen by the features, now while i was trying to create a panel of type table, for some reason i am unable to get certain columns in the table, the query works directly in clickhouse but on signoz dashboard it leaves certain columns from the output. attaching the CH query i am using and a SS showing the issue. TIA!
Copy code
SELECT
    name as table_name, database, ((total_bytes/1024)/1024) as value
FROM system.tables
ORDER BY value DESC
1
s
Do you see any errors in query-service logs?
h
actually yes when i checked now, getting this log repeatedly for 5,6 times when my query is executed.
Copy code
{
  "level": "ERROR",
  "timestamp": "2024-06-20T17:31:21.968Z",
  "caller": "clickhouseReader/reader.go:4543",
  "msg": "unsupported var type found in query builder query result",
  "v": 124.10833358764648,
  "colName": "value",
  "stacktrace": "<http://go.signoz.io/signoz/pkg/query-service/app/clickhouseReader.readRow|go.signoz.io/signoz/pkg/query-service/app/clickhouseReader.readRow>\n\t/home/runner/work/signoz/signoz/pkg/query-service/app/clickhouseReader/reader.go:4543\ngo.signoz.io/signoz/pkg/query-service/app/clickhouseReader.readRowsForTimeSeriesResult\n\t/home/runner/work/signoz/signoz/pkg/query-service/app/clickhouseReader/reader.go:4584\ngo.signoz.io/signoz/pkg/query-service/app/clickhouseReader.(*ClickHouseReader).GetTimeSeriesResultV3\n\t/home/runner/work/signoz/signoz/pkg/query-service/app/clickhouseReader/reader.go:4660\ngo.signoz.io/signoz/pkg/query-service/app/querier/v2.(*querier).execClickHouseQuery\n\t/home/runner/work/signoz/signoz/pkg/query-service/app/querier/v2/querier.go:95\ngo.signoz.io/signoz/pkg/query-service/app/querier/v2.(*querier).runClickHouseQueries.func1\n\t/home/runner/work/signoz/signoz/pkg/query-service/app/querier/v2/querier.go:420"
}
s
Strange error. Seems like some double pointer type is returned. The work around I can suggest is to type cast the value to string and check.
h
hey casting to string worked, thank you for the suggestion,I don't know in depth of the clickhouse nor signoz to comment on the error so i will that to your skilful hands. Thanks a lot!
attaching the updated query in case someone stumbles on this.
Copy code
SELECT
    name as table_name, database, if(total_bytes>0,cast((total_bytes/1024)/1024, 'String'),'0')  as value
FROM system.tables
ORDER BY value DESC
s
Can you create an issue here https://github.com/SigNoz/signoz